49AV-WRF SIMPLEX

$113.58

Available on backorder

SKU: 49AV-WRF Category:

Description

49AV-WRF Simplex, AV, Wall Red Fire.

This is the 49AV-WRF Simplex, TrueAlert ES addressable A/Vs are individually addressed audible/ visible notification appliances that receive power, supervision, and control signals from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs).

Audible notification appliance (horn)

  • Harmonically rich output sound for either coded or steady operation.
  • Horns sound as Temporal Code 3, March Time pattern, continuous; or Temporal Code 4, controlled separately from visible appliances on the same two-wire circuit.
  • Selectable March Time rates of 20, 60, or 120 beats per minute.
  • The output is “high” or “low” (~5 dBA difference) selectable at the appliance or from the controller with FACP mode selected at the appliance.

Individually addressed and controlled multi-candela TrueAlert ES A/V (audible/visible) notification appliances provide:

  • Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, 110, 135, or 185 cd.
  • Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup.
  • Wiring supervision to each appliance allowing “T-tapped” connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring).
  • Self-Test Mode allows onboard sensors to detect the strobe and horn output and then report their status to the control panel.
  • TrueAlert Device Reports Reports are available at the control panel detailing appliance point ID, custom label, type, and candela setting.
  • Magnet Test diagnostics assist checkout and testing of appliances and wiring.
  • Electrical test point access Access the electrical test point without removing the cover.
  • Compatibility with ADA requirements.
  • Compatibility with legacy TrueAlert addressable systems for upgrade and replacement.
  • Strobe operation is listed to UL Standard 1971 and ULC Standard S526; Horn operation is listed to UL Standard 464 and ULC Standard S525.

Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

Datasheet 49AV-WRF.

See all our parts forĀ Simplex

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Product Brand

Simplex

MPN

49AV-WRF

Product Category

1871